Type: | Floor Heating | Voltage: | AC230V, 50Hz |
---|---|---|---|
Current Load: | 16A | Setting Range: | +5~+60℃ |
Floor Sensor: | NTC Sensor | Accuracy: | 0.5ºC |
High Light: | digital touchscreen thermostat,touch screen heating thermostat |
CE under tile electric floor heating cable mat thermostat
Touch Screen Period Programming Thermostat Weekly circulation, it is possible to set 6 periods called events each day with corresponding pre-set temperatures, also you can select "period control mode" or "manual mode" according to your individual requirements.
Technical data
Power Supply | AC200-240VAC 50/60HZ |
Accuracy | ±0.5ºC |
Probe sensor | NTC |
Power Consumption | <0.3W |
Load current | 3A(water heating),16A(electric heating) |
Temperature Adjustable Range | 5°C~60°C( can adjust to 35°C~60°C) |
Limit Temperature Range | 5°C~60°C( factory setting: 35°C) |
Output | Switch relay |
Insulating condition | Normal environment |
Running program | Set per 1 week as a cycle |
Installation | Wall mounted |
Application | Water Floor Heating System |
Electric Floor Heating System | |
Infrared Heater System | |
Certificate | CE,RoHS |
A / AF/ F models all in one
Combination of 3 models;
A - Air only, with built-in sensor;
F - Floor only,controls floor temperature;
AF - Controls air temperature with ability to limit the
floor temperature
Each thermostat is equipped with built-in sensor
and a 3 meter floor sensor. The floor sensor can be extended.
Useful settings
Vacation mode(frost protection mode)
Switching differential setting
Floor temperature limit
Advanced setting (qualified person preferred)
You can press "M" and"Time"and hold for 5 seconds at the same time to enter the mode of advanced setting when the thermostat is turned off. The following seven function can be chosen by pressing "M".
Symbol | Setting | Up or Down | |
1 | ADJ | Temperature calibration | Adjust measured temperature |
2 | SEN | Sensor mode |
IN: built-in sensor |
3 | LIT | Limitation temperature |
Adjust limitation value, |
4 | DIF | Switching differential | Adjust switching differential |
5 | LTP | Antifreeze function | Turn on/off Anti-frozen function |
6 | PRG | Set vacation mode |
2: 5/2 day mode |
7 | RLE | Potential-free output |
00: in same way |
8 | DLY | Potential-free output delay | Change the delay time |
9 | HIT | Max. Temperature | Max. Limitation temperature set point (99℃) |
10 | AFAC | Reset to factory settings | Programming parameters will be reset to factory settings when symbol "" appears |
Writing Diagram
Sensor failure
Please select the right sensor mode when operation, it will display the "Err" symbol on screen far sensor failure, thermostat must be checked till the fault is eliminated.