Place of Origin: | Jiangsu |
Brand Name: | Saiko |
Certification: | CE |
Model Number: | SK82 |
Minimum Order Quantity: | 50PCS |
---|---|
Price: | Negotiation |
Packaging Details: | 1pc/inner box, 50pcs/carton |
Delivery Time: | 10 WORKDAYS |
Payment Terms: | T/T, Western Union, L/C |
Supply Ability: | 8000PCS/WEEK |
Type: | Floor Heating | Voltage: | 230V,50Hz |
---|---|---|---|
Setting Range: | 5-35℃ | External Limitation: | 5-60℃ |
Housing Material: | Anti-flammable PC | Current: | 16A |
High Light: | digital touchscreen thermostat,touch screen heating thermostat |
LCD touch screen weekly programmable electric floor heating thermostats
Weekly circulation digital programming thermostat with LCD screen, which has 6-event everyday. Manual mode and programme mode could be selected. The thermostat is recommended for control of electric heating devices or on/off valve actuator used in hydronic floor heating.
Programming
Choice of 7 day, 5/2 day programmable or
non-programmable (installer selectable);
6 time and 4 temperature settings every day;
pre-programmed or personalized schedule;
Display
Large, touchscreen display;
European standard installation box;
White lighted display for easier low-light viewing;
Larger, easy-to-read character size;
Intuitive menu-driven set-up, programming and operation,
Permanent program retention during power loss;
Setpoint temperature limited range capable;
Enhanced touchscreen security prevents tampering.
Can switch upto 16 amps (230v)
A / AF/ F models all in one
Combination of 3 models;
A - Air only, with built-in sensor;
F - Floor only,controls floor temperature;
AF - Controls air temperature with ability to limit the
floor temperature
Each thermostat is equipped with built-in sensor
and a 3 meter floor sensor. The floor sensor can be extended.
Sensor failure
Please select the right sensor mode when operation, it will display the "Err" symbol on screen far sensor failure, thermostat must be checked till the fault is eliminated.
Specifications
Power Supply | AC200-240VAC 50/60HZ |
Accuracy | ±0.5ºC |
Probe sensor | NTC |
Power Consumption | <1W |
Load current | 3A(water heating),16A(electric heating) |
Temperature Adjustable Range | 5°C~60°C( can adjust to 35°C~60°C) |
Limit Temperature Range | 5°C~60°C( factory setting: 35°C) |
Output | Switch relay |
Insulating condition | Normal environment |
Running program | Set per 1 week as a cycle |
Installation | Wall mounted |
Application | Water Floor Heating System |
Electric Floor Heating System | |
Infrared Heater System | |
Certificate | CE,RoHS |
Useful settings
Vacation mode(frost protection mode)
Switching differential setting
Floor temperature limit
Packing details
1pc/inner box, 50pcs/carton
Carton size: 51x22x36cm
Writing
Attention:
The thermostat which connect the electric heating device is apply to full load(3200w)heating cable in 2500m height above sea level,and the rated power of external load should be less than or equal to 80% rated power thermostat when in the 2500m to 4200m height.
Sensor Failure
E1:Built-in sensor short-circuited or disconnected.
E2:External sensor short-circuited or desconnected.
When shows E1/E2 error,thermostat must be checked till the error is eliminated.